sas2flsh -o -f 2118it. Flash the card with the LSI 9211-8i Firmware. 如何将LSI9240(IBM M1015)改刷IT Mode固件 图1. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die “-” Zeichen # -b mptsas2. bin -b mptsas2. But I guess when you have an older motherboard with which sas2flsh. done with the undocumented command sas2flsh -o -e 7. Rest are duplicates, perhaps SSD modules are actually dual ported SAS rathern than SATA like everyone assumes. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. I'm having trouble getting this card to work properly. bin; It will interrupt you to ask you a question. efi -o -sasadd 5000112233445566 9> 重启电脑,完成,即可! 大概的流程就是这样了,不出意义都可以正常刷入的了,附件非常适合大众使用. sas2flsh -sasadd. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. 4) Reboot the system. rom (sas2flsh o f 2118it. PAN Fehler : Entweder älteres Board nehmen oder per EFI flashen. rom sas2flsh -o -f 2118it. After this is complete, you can do sas3flash. Home › Home Lab › IBM M1015 9220-8i cross-flashed to LSI 9211-8i IT mode. efi -listall command now shows us the new Firmware and BIOS applied to both cards. これで完了です。 上手いこといってれば、M1015が9210-8iとして起動して、 起動時に挿したディスクがそのまま見えているはずです。. rom (sas2flsh -o -f 2118it. sas2flsh -o -f 2118it. In Linux The card works out of the box in Linux. The same steps will flash the card to a LSI 9211-8i. As above, the -c 0 and -c 1 at the end of these commands specify the controller number. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die “-” Zeichen # -b mptsas2. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. efi -o -sasadd 500605XXXXXXXXXX. sas2flsh -o -sasadd 500605bxxxxxxxxx sas位置在卡上背後黃色貼紙 500605bxxxxxx 不要加- 一個已刷10張卡的人筆記. Using the 2308 controller chip found on the ASRock Extreme 11 motherboard and I have eight 128 GB OCZ Vertex 4 SSD's (Firmware 1. sas2flsh -o -f 2118it buy cytotec online. rom (You can omit the "-b mptsas2. sas2flsh -o -c 2 -f 2118it. bin -b mptsas2. sas2flsh -o -sasadd 500605b0XXXXXXXX replace the xxx with the value written (hopefully) on the card. exe erwähnt. exe - утилита для работы с контроллерами LSI, образы BIOS и firmware (в контроллерах на базе LSI 2008 bios и fw шьются отдельно) 2. exe -o -sasadd 500xxxxxxxxxxxxx; H310 UEFI Run the following commands in the DOS prompt: megacli. bin = IT mode Firmware, change according to which way to flash) sas2flsh - o - sasadd 500605bxxxxxxxxx ( x = numbers for SAS address ) < reboot >. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (試好久都弄不成,到底SAS address要看哪裡?? xxxxxxxxx 要改為什麼?). sas2flsh -o -f 2118it. sas2flsh -o -f 2118ir. Now to actually do the deed: In my MB, if I bring up the boot menu by pressing F11, one of the options is "Built-in EFI Shell". bin -c 0 sas2flsh -o -f 2118it. Flashing your Dell Perc H310 to IT firmware (UEFI) 6 March 2015 30 July 2015 ciamician I've been lucky enough to acquire a second-hand Dell H310 RAID controller card, which I'll be using in my future ZFS build. 执行 sas2flsh -o -f 214i4et. If you don't have this, I searched and saw there are bootable linux distros what come with EFI shells. bin -b mptsas2. only done sith the dos utility and the -sasadd command. exe -listall (to find adapter number… usually "0") 2) sas2flsh. Die Fehlermeldung erscheint bei Hauptplatinen mit UEFI oder auf inkompatiblen Mainboards. # sas2flsh -o -f 2118it. Can anyone help? When it first arrived, I plugged it all in to test it wasn't a dud and booted the system, BIOS Option ROM appears, detects the 1 drive I currently have hooked up to it for testing, prompts to press a key to continue because the config has change (no RAID arrays configured) - press key, then system continued to boot into. Post navigation. Preparing an LSI SAS 2008 based controller for ZFS In my last post I wrote about how the Adaptec 5805 RAID controller was the wrong choice for our backup server. Program SAS Address -sasadd 5 Y Num1 Program the selected controller with SAS address from num1. Die x durch die notierten Zeichen ersetzen (SAS Adresse) Stick entfernen und den Rechner neustarten. Có thế khi người ta đọc vào không hiểu. Llegados a este punto, o tenemos una HBA, o algo con que sujetar la puerta. efi -o -sasadd 500605XXXXXXXXXX. In the next command, replace “500605bxxxxxxxx” with the SAS number you found on the controller earlier and wrote down. PAN Fehler : Entweder älteres Board nehmen oder per EFI flashen. exe -o -sasadd Ya hemos acabado. bin -b mptsas2. bin controller firmware and the mptsas2. (忘れた場合でも、カードにバーコード付のシールが貼ってあって、そこに書いてあるはず) sas2flsh -o -sasadd 500605bxxxxxxxxx. Sau bước này chúng ta đã hoàn thành quá trình flash lại IT firmware cho các card RAID thông dụng và chi phí rẻ. You're done When you now reboot you should see the new firmware on the card:. When I issued this command, I saw the results were good:. _jkh_: nik_: I mean, if you're going to punch the HDs through then that certainly removes some of the classic caveats (ZFS likes to own the disks directly) but without more to the picture, ESXi doesn't really add anything either, unless your hardware is just grossly overspec'd and you want to use it for multiple VMs. Flashing IT mode in UEFI shell: For all X9 MB. bin -c 0 sas2flsh -o -f 2118it. > sas2flsh -o -sasadd 500605bxxxxxxxxx: 8. bin -b mptsas2. This is the part where we replace the Dell HBA FW with LSI 9211-8i FW; Boot from USB and run the following command to flash the LSI firmware: sas2flsh. bin megarec -cleanflash 0 sas2flsh -o -f 2118it. done with the undocumented command sas2flsh -o -e 7. exe -o -f 6GBPSAS. Flash the controller with the new firmware with IT-mode with sas2flsh -o -f 2118it. Since then I've been having strange issues with my IBM M1015 controller. bin instead of the 6GBPSAS. Yes, this is possible. exe -o –sasadd 50030480070a8b00. fw If flashing a M1015 you can use the 2118p7. bin if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). sas2flsh -o -sasadd 500605b001bdcc32 "500605bxxxxxxxxx" 这个号在你的卡上有一标签上可以找到,500605B开头, 去掉 "-"。 刷完后启动,卡bios自检时会显示 "sas2008-IT" ,没改前是"sas2008-IR" 具体后面有图哈。. Flashing RAID controller firmware on OpenSUSE Is there software that would allow me to flash RAID controller firmware on OpenSUSE? I have the following guide to flash my Dell H310 SAS2/SATA3 6Gbps 8 port controller to HBA mode. regression testing all the bits of the puzzle I'm trying to assemble, to make sure that in isolation, each virtual machine's OS will work with the hardware concerned. Preparing an LSI SAS 2008 based controller for ZFS In my last post I wrote about how the Adaptec 5805 RAID controller was the wrong choice for our backup server. sas2flsh -o -f 2118it. exe - утилита для работы с контроллерами LSI, образы BIOS и firmware (в контроллерах на базе LSI 2008 bios и fw шьются отдельно) 2. rom Don't forget to readdress your card with its SAS address, or its not going to be able to find your drives sas2flsh -o -sasadd <5006xxxxxxx> ## Sticker or printed on the board ## If you have issues you can restore your SBR with megarec -writesbr 0 backup. Die Sterne sind die Zahlen vom grünen Sticker hinter 500605b Mit dem Befehl "sas2flsh -o -sasadd 500605b*****" 5. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (en remplaçant les x par le code copié précedemment sans les -) Et voilà c’est fini, il suffit de booter sur votre serveur (pensez à retirer la clé USB bootable). megarec -writesbr 0 sbrempty. Mit dem Befehl "sas2flsh -o -f 2118ir. This guide will outline the steps to flash a PERC H200 with LSI-9211-8i firmware to IT mode to allow direct disk access on an R710. ついでにsas2flsh. bin -b mptsas2. rom sas2flsh -o -sasadd 500605bxxxxxxxxx where the xxxx stuff is from the back of my card. Will be used as centralized home storage, with some light virtualization and backup duties. Llegados a este punto, o tenemos una HBA, o algo con que sujetar la puerta. 9240-8i阵列卡对于数据恢复来说,需要一个可以直接读取裸硬盘的HBA阵列卡(即IT model),以将阵列中所有成员盘识别为独立硬盘来进. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. efi -listall command now shows us the new Firmware and BIOS applied to both cards. sas2flsh -sasadd. Có thế khi người ta đọc vào không hiểu. 闲说云服务是三分开发七分运维???好像说的并没有错啊!o(╯ ╰)o今天运维公司对象存储系统,发现坏盘,联系网络组换盘,结果网络组希望我提供坏盘的Slot位置。. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (en remplaçant les x par le code copié précedemment sans les -) Et voilà c'est fini, il suffit de booter sur votre serveur (pensez à retirer la clé USB bootable). exe -o -f 6GBPSAS. rom(Update bios Ver). exe -cleanflash 0. 发布时间:2017-05-02 来源:服务器之家. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. sas2flsh -o -f 2118ir. This is helpful for situations where direct disk access is preferred over a RAID configuration, for instance, for use with a FreeNAS installation. Because the motherboard supports EFI, a DOS boot disk created by rufus is not sufficient to complete this procedure. sas2flsh -o -sasadd 500605b0xxxxxxxx. sas2flsh -o -f 2118it. Yes, this is possible. rom (sas2flsh -o -f 2118it. bin controller firmware and the mptsas2. net元スレ自作PC板に戻る全部最新50 終了したスレッドです. Exiting program" on my SuperMicro X10 motherboard when trying to do anything with that tool in DOS. In the next command, replace “500605bxxxxxxxx” with the SAS number you found on the controller earlier and wrote down. sas2flsh -o -f 2118it. I'm having trouble getting this card to work properly. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" Despite me missing this, it is humming away nicely in my now converted production box on 5. exe -o -f 2118it. sas2flsh -c 0 -list. exe -o -sasadd XXXXXXXXXXXXXXXX" Your SAS address Restart and check SAS address Finish. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Reboot, again booting from the USB stick Finally, upgrade to the P20 firmware – type the following to change to the folder and execute flash of the new firmware:. sas2flsh -o -f 6GBPSAS. Description Of Change: When the driver gets a TUR reply as part of LUN reset processing ,with a UAR in sense data, the UAR state machine kicks off and the state machine sends ATS, once ATS is processed, resume the adapter only for Reset SRB. fw firmware. exe -o -f 6GBPSAS. PAN Fehler : Entweder älteres Board nehmen oder per EFI flashen. bin; It will interrupt you to ask you a question. fw The card has been erased but it still thinks it is a raid card, we have to use the manu factor unraid firmware to convert it to unraid Sas2flsh. Convert LSI9240(IBM M1015) to a LSI9211IT mode Type in the following exactly: megarec writesbr 0 sbrempty. Mit dem Befehl "sas2flsh -o -f 2118ir. 如何将LSI9240(IBM M1015)改刷IT Mode固件 图1. sas2flsh -o -sasadd 500605bxxxxxxxxx (x= “MY’ 9 digits on sticker for SAS address) Rick January 27, 2012 at 2:37 pm Took a chance and succeeded in changing the M1015 from “factory’ to IT Mode w/o the boot bios being re-flashed back in. Will be used as centralized home storage, with some light virtualization and backup duties. sas2flsh -o -f 2118ir. Reboot the computer and boot back into the USB drive. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Reboot, again booting from the USB stick Finally, upgrade to the P20 firmware – type the following to change to the folder and execute flash of the new firmware:. This is helpful for situations where direct disk access is preferred over a RAID configuration, for instance, for use with a FreeNAS installation. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (500605bxxxxxxxxxは上記のボードからメモったaddressを記載) 再度、再起動します。 コレでHBA化は完了しているはずです。. In Linux The card works out of the box in Linux. Elore is koszonok minden javaslatot. > sas2flsh -o -e 6 Then you can jump back a few lines above to re-flash the 6gbpsas. #freenas IRC Archive. UEFI LSI SAS 3008 Sasadd. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. Rest are duplicates, perhaps SSD modules are actually dual ported SAS rathern than SATA like everyone assumes. Type it in, without any “-“, “:” or other special characters, only letters and numbers in one string. bin -b mptsas2. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. sas2flsh-o-f 2118ir. Hi Michael, Thanks so much for this, I was getting pretty worried about my FreeNAS install when my old Dell Poweredge T310 with the PERC H200 gave me the "Firmware version 2 does not match driver version 16 for /dev/mps0" in FreeNAS Alert. rom (sas2flsh -o -f 2118it. Flash the new firmware: sas2flsh -o -f 2118ir. 26 thoughts on " Crossflashing Dell PERC H200 to LSI 9211-8i " John E 2014-12-21 at 02:32. This is the part where we replace the Dell HBA FW with LSI 9211-8i FW; Boot from USB and run the following command to flash the LSI firmware: sas2flsh. ) There are a couple of things to note here. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. rom bit from the firmware reflash step. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. The first is sas2flsh, which is an executable used to install firmware images. Quiero montar 2 volúmenes RAID0 por hardware en un pc con windows 10. exe in the downloaded package from the ServeTheHome article with the one from LSI's Support Page The board is up and running in the ESXi host now and I will run some benchmarks to compare the performance difference between a Datastore image, a Raw Device Mapped (RDM) drive and a drive connected to the LSI controller and. 1) Please copy all files from UEFI folder to bootable USB disk. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (en remplaçant les x par le code copié précedemment sans les -) Et voilà c’est fini, il suffit de booter sur votre serveur (pensez à retirer la clé USB bootable). Fertig - System neustarten und freuen. exe -o -f 6GBPSAS. Using the 2308 controller chip found on the ASRock Extreme 11 motherboard and I have eight 128 GB OCZ Vertex 4 SSD's (Firmware 1. Continuing from my last post, I was able to join modern times by adding an SSD to my circa-2011 gaming system. To load the actual firmware, you run these commands: sas2flsh -o -f 2118it. 6a+ compatible controller. Ordered some parts for a FreeNAS build Monday night. bin Yes/No라고 물으면 Y입력 재부팅 후 사용하던 OS로 부팅. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. bin-b mptsas2. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. Please try again later. Yes, this is possible. sas2flsh -o -sasadd 500605b001bdcc32 5 u: O, j4 }# P- g7 X "500605bxxxxxxxxx" 这个号在你的卡上有一标签上可以找到,500605B开头, 去掉 "-"。. IBM M1015 9220-8i cross-flashed to LSI 9211-8i IT mode By c0demech on March 22, 2018 • ( 0). I'm having trouble getting this card to work properly. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. rom (sas2flsh -o -f 2118it. The performance improvements have been fantastic and I couldn't be happier with the decision to upgrade. bin(如果要更新为IR模式请Update2118ir. At this point I connected the SSD to the card and moved the card to the first position in the motherboard boot order. bin (失败就可以往下执行) megarec -cleanflash 0(将阵列卡信息清空) 重启. One of the most popular SAS 6. 9240-8i阵列卡对于数据恢复来说,需要一个可以直接读取裸硬盘的HBA阵列卡(即IT model),以将阵列中所有成员盘识别为独立硬盘来进. Zum Schluss die SAS Adresse eingeben. exe -o -sasadd Ya hemos acabado. efi -o -sasadd 50060XXXXXXXXXXXX. bin -b mptsas2. Mit dem nächsten Neustart des Systems ist die PCI-Karte nun im IT-Mode und betriebsbereit. 6a+ compatible controller. efi-o-sasadd 500605bxxxxxxxxx This entry was posted in Hardware and tagged firmware , ibm , LSI , ServerRaid on March 12, 2014 by Sean. ### START d1851bb004ead848f18f828f8fd48bae #3812 Feature Nice to have include htop #3879 Feature Expected Translate RRD data from collectd into something that we. rom controller BIOS. 6) sas2flshでファームを書き換えます。 書き換えたいbinを選びます。 IT(HBA)化 sas2flsh -o -f 2118it. > sas2flsh -o -e 6 Then you can jump back a few lines above to re-flash the 6gbpsas. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. sas2flsh -o -c 2 -f 2118it. sas2flsh -o -e 6. sas2flsh -o -sasadd 500605b001bdcc32 5 u: O, j4 }# P- g7 X "500605bxxxxxxxxx" 这个号在你的卡上有一标签上可以找到,500605B开头, 去掉 "-"。. Will be used as centralized home storage, with some light virtualization and backup duties. > sas2flsh -o -f 2118ir. Берем блокнот с записанным SAS адресом и вводим его после команды: sas2flsh -o -sasadd. fw The card has been erased but it still thinks it is a raid card, we have to use the manu factor unraid firmware to convert it to unraid Sas2flsh. rom controller BIOS. bin -b mptsas2. rom 12) Program original SAS address: sas2flsh -o -sasadd 500605BXXXXXXXXX Note: replace 500605BXXXXXXXXX with the number on your card (omit '-'). exe -o -f 6GBPSAS. sas2flsh -o -f 2118it. rom (sas2flsh -o -f 2118it. centos xcb Lsi卡和IB卡在CentOS中升级. rom sas2flsh. Can anyone help? When it first arrived, I plugged it all in to test it wasn't a dud and booted the system, BIOS Option ROM appears, detects the 1 drive I currently have hooked up to it for testing, prompts to press a key to continue because the config has change (no RAID arrays configured) - press key, then system continued to boot into. ### START d1851bb004ead848f18f828f8fd48bae #3812 Feature Nice to have include htop #3879 Feature Expected Translate RRD data from collectd into something that we. exe -o -sasadd 500xxxxxxxxxxxxx (replace this address with the one you wrote down in the first steps). Preparing an LSI SAS 2008 based controller for ZFS In my last post I wrote about how the Adaptec 5805 RAID controller was the wrong choice for our backup server. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. Convert LSI9240(IBM M1015) to a LSI9211-IT mode Type in the following exactly: megarec -writesbr 0 sbrempty. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (en remplaçant les x par le code copié précedemment sans les -) Et voilà c’est fini, il suffit de booter sur votre serveur (pensez à retirer la clé USB bootable). > sas2flsh -o -sasadd 500605bxxxxxxxxx: 8. The address is on a sticker on the card, and is of the form '500605b X-XXXX-XXXX' where the X's are different for each card. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Reboot, again booting from the USB stick Finally, upgrade to the P20 firmware - type the following to change to the folder and execute flash of the new firmware:. Need help with H200, FreeNAS, and Dell R710 Discussion in ' sas2flsh. I'm having trouble getting this card to work properly. Home › Home Lab › IBM M1015 9220-8i cross-flashed to LSI 9211-8i IT mode. rom = kann man weglassen, wenn man kein Option ROM (BIOS) benötigt, bootet. bin Yes/No라고 물으면 Y입력 재부팅 후 사용하던 OS로 부팅. Llegados a este punto, o tenemos una HBA, o algo con que sujetar la puerta. Since then I've been having strange issues with my IBM M1015 controller. net元スレ自作PC板に戻る全部最新50 終了したスレッドです. Turning Dell PERC H310 to dumb biosless SAS / SATA controller After realizing that LSI SAS1078 based controller wouldn't do what I want I ended up purchasing card from eBay, 65€ including shipping for unused, new in box Dell PERC H310. Juuh elikkäs. sas2flsh -o -f 2118it. Flash the controller with the new firmware with IT-mode with sas2flsh -o -f 2118it. 6a+ compatible controller. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). bin -b mptsas2. rom sas2flsh -o -f 2118it. 0gbps/ SATA III controllers for enthusiasts is the IBM M1015. efi-o-sasadd 500605bxxxxxxxxx This entry was posted in Hardware and tagged firmware , ibm , LSI , ServerRaid on March 12, 2014 by Sean. exe -c 0 -list (ensure it's your address, and not all zeros) 3) reboot and enjoy. When I issued this command, I saw the results were good:. Enterprise Products, Solutions and Services for Enterprise. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). https://forums. I was trying to get an H200 flashed and running in a Dell R710 and after flashing I could not get it to appear as a boot device no matter what I did. Flashing RAID controller firmware on OpenSUSE Is there software that would allow me to flash RAID controller firmware on OpenSUSE? I have the following guide to flash my Dell H310 SAS2/SATA3 6Gbps 8 port controller to HBA mode. The same steps will flash the card to a LSI 9211-8i. The address is on a sticker on the card, and is of the form '500605b X-XXXX-XXXX' where the X's are different for each card. The final file is mptsas2. rom sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) The SAS address is found on the back of the card, on the green sticker. Zum Schluss die SAS Adresse eingeben. Elore is koszonok minden javaslatot. That motherboard has been discontinued. bin if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Jag fastnat dock på raden. namely sas2flsh -o -sasadd 500605b***** Not sure what this does myself. Will be used as centralized home storage, with some light virtualization and backup duties. C:\> s2fp19. ##IBM ServeRAID M1015: crossflashing to a LSI9211-8i IR/IT Mode. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). rom; Program SAS address in IT-mode where 500605b***** is the code on the green sticker on your RAID card without the "-" with sas2flsh -o -sasadd 500605b***** Done for this time! Enjoy your reflashed LSI 9240-8i which is now an LSI 9211-8i!. sas2flsh-o-sasadd 500605b003cc2720 Nachdem der Befehl eingegeben und mit der Enter-Taste bestätigt wurde, ist der Flashvorgang abgeschlossen. Ibm m1015 sas address 2019-10-14 02:39. Flash the controller with the new firmware with IT-mode with sas2flsh -o -f 2118it. Can anyone help? When it first arrived, I plugged it all in to test it wasn't a dud and booted the system, BIOS Option ROM appears, detects the 1 drive I currently have hooked up to it for testing, prompts to press a key to continue because the config has change (no RAID arrays configured) - press key, then system continued to boot into. bin -b mptsas2. sas2flash -o -sasadd SSSSSSSSSSSSSSSSSSSSSSSS sas2flash -o -assem AAAAAAAAAAAAAAAAAAAAAAA sas2flash -o -tracer TTTTTTTTTTTTTTTTTTTTTTT 4)检查 运行命令. efi -listall command now shows us the new Firmware and BIOS applied to both cards. Có người nói với tôi rằng, khi làm một bài hướng dẫn cứ viết ngăn ngắn, không tội gì phải viết cặn kẽ dài dòng. rom sas2flsh -o -f 2118it. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. bin -b mptsas2. exe -o -f 2118it. a boot disk with the utils can be found here. In its native form, it is a very capable host bus adapter (HBA) based on the LSI SAS2008 chip. Broadcom Inc. For what it's worth, if you're not a) booting from a drive attached to your SAS adapter (if you're using FreeNAS, the answer to that is probably "no") and b) not attempting to make use of staggered spin-up mode on your SAS-attached drives, you'll likely be better off to drop the -b mptsas2. regression testing all the bits of the puzzle I’m trying to assemble, to make sure that in isolation, each virtual machine’s OS will work with the hardware concerned. Fertig! Fehler beim Flashen. In Linux The card works out of the box in Linux. After this is complete, you can do sas3flash. efi -o -sasadd 50060XXXXXXXXXXXX. Текущая версия firmware-пакета - 20, внутри архива будут: sas2flsh. Congratulations, you are ready to go after a reboot. 9240-8i阵列卡对于数据恢复来说,需要一个可以直接读取裸硬盘的HBA阵列卡(即IT model),以将阵列中所有成员盘识别为独立硬盘来进. Redémarrer Fini! Petit Bonus: Si vous choisissez le mode IT, il n'y a plus d'intérêt à charger le bios de la carte (puisqu'aucune action n'est possible!). 如何将LSI9240(IBM M1015)改刷IT Mode固件 图1. bin -b mptsas2. Flash the card with the LSI 9211-8i Firmware. sas2flsh -o -f 6gbpsas. bin controller firmware and the mptsas2. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (試好久都弄不成,到底SAS address要看哪裡?? xxxxxxxxx 要改為什麼?). Fertig! Fehler beim Flashen. bin if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Jag fastnat dock på raden. Since then I've been having strange issues with my IBM M1015 controller. rom sas2flsh -o -sasadd 500605b0xxxxxxxx GEHT NICHT und nachher ist kein firmwareupdate möglich! einziges heilmittel SBR und SAS Adresse gut aufheben!. _jkh_: nik_: I mean, if you're going to punch the HDs through then that certainly removes some of the classic caveats (ZFS likes to own the disks directly) but without more to the picture, ESXi doesn't really add anything either, unless your hardware is just grossly overspec'd and you want to use it for multiple VMs. bin -c 0 sas2flsh -o -f 2118it. exe -o -sasadd 5xxxxxxxxxxxxxxx Achtung! Mögliche -(Bindestriche) weglassen. 发布时间:2017-05-02 来源:服务器之家. sas2flsh -o -f 2118it. rom (sas2flsh -o -f 2118it. sas2flsh -listall sas2flsh -o -e 6 sas2flsh -o -f xxxx. It's my first foray into ZFS. exe -o -f 6GBPSAS. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. As above, the -c 0 and -c 1 at the end of these commands specify the controller number. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. The first is sas2flsh, which is an executable used to install firmware images. bin -b mptsas2. 6a+ compatible controller. sas2flsh -o -f 2118ir. I was using an ASRock extreme6 with 10 SATA ports. rom (sas2flsh o f 2118it. sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Done! I thought this^ above was a little less clear so I provided the extra in the steps above for basic help so a newbie will know what to do without making the mistakes that are common. exe -o -sasadd Ya hemos acabado. These steps will work for both an onboard controller or an add-in card. When I issued this command, I saw the results were good:. One of the most popular SAS 6. Tämä komento tyhjentää myös kaikki tehtaalla asetetut asetukset, kuten kortin tyypin ja SAS WWN-osoitteen, jolloin se pitää asettaa uudelleen firmwaren asennuksen jälkeen komennolla. Request some help for those who know about the LSI controllers. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. exe -o –sasadd “Controller SAS address” For example: sas2flsh. Need help with H200, FreeNAS, and Dell R710 Discussion in ' sas2flsh. Flashing your Dell Perc H310 to IT firmware (UEFI) 6 March 2015 30 July 2015 ciamician I've been lucky enough to acquire a second-hand Dell H310 RAID controller card, which I'll be using in my future ZFS build. exe -listall (to find adapter number… usually "0") 2) sas2flsh. Rest are duplicates, perhaps SSD modules are actually dual ported SAS rathern than SATA like everyone assumes. [[email protected] ~]# lspci|grep LSI. 5) set up in RAID 0. bin(如果要更新为IR模式请Update2118ir. sas2flsh -o -e 6 Going the other way, back to 2208 firmware. sas2flsh -o -f 2108it. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). > sas2flsh -o -e 6 Then you can jump back a few lines above to re-flash the 6gbpsas. efi -o -sasadd 500605XXXXXXXXXX. rom sas2flsh -listall. You're done When you now reboot you should see the new firmware on the card:. Se usarían 8 discos duros en total.
Post a Comment